SAE Global Supplier Marketplace
Login / MySAE  |  Sign Up!
SAE Home Industries
Search: Advanced Search

Magazine eMedia Advertising Info Contact Us

Fuel-cell testing

More 1 2 3 4

Fuel-cell Parameters to be Monitored and Controlled
ItemChannel typeSignal conditioning
VoltageAnalog inputIsolation, attenuation
CurrentAnalog inputScaling attenuation
PressureAnalog inputScaling
HumidityAnalog inputScaling
Flow rateCounter inputScaling
TemperatureAnalog inputScaling, amplification, excitation
Emergency shutoffDigital outputSwitching
Nitrogen purgeDigital outputSwitching
Pressure valvesAnalog outputAmplification
Heater and fansGPIB or digital outputSwitching (with digital output)
LoadGPIB or digital outputSwitching (with digital output)

Fuel-cell Testing Hardware Components
ItemDescription
PC/PXI controllerPerforms the test execution and data storage
PC/PXI chassisHouses controller and I/O components
Multifunction I/OPerforms the analog to digital conversion and controls the conditioning
RelaysRoutes power output
Analog outputControls pressure valves
Isolated/amplified analog inputMonitors voltage and current
Isolated thermocouple inputMonitors temperature from thermocouples
Isolated digital outputControls shutoff, bypass, and purge valves
Programmable loadAbsorbs power output of fuel cell
Mass flow controllerControls gas flow
Fixturing/pipingRoutes gases into and out of fuel cell

©2009 SAE International. All rights reserved.